CIDEX OPA Solution is a quick and effective high-level disinfectant used on a broad variety of semi-disquisitional, oestrus-sensitive medical devices in medical facilities all over the globe. CIDEX OPA is very constructive against a wide range of microorganisms has a almost neutral pH level.

CIDEX OPA Solution provides a quick five-minute advanced sterilization for disinfection in an automatic endoscope reprocessor at 25º C or more, or in 12 minutes at 20º C candy manually. No other new high-level disinfectant with such broad material compatibility like a glutaraldehyde solution has been made available in the last xxx years. Specifically targeting a wide range of mycobacteria, similar strains of glutaraldehyde solution resistant One thousand.chelonae.

CIDEX OPA solution is ready to apply correct from the bottle and does not crave activation or mixing. CIDEX products are a vital link in the chain of modern medical facility disinfection for medical and surgical facilities. While it is used extensively in medical facilities, information technology is besides used for items such as SCUBA (cocky-contained breathing apparatus) gear past non-medical personnel.

How to Use CIDEX OPA to Disinfect Medical Equipment

The steps to apply CIDEX activated dialdehyde disinfectant solution every bit a high-level disinfectant in a medical setting are:

  • Vesture Your Personal Protective Equipment
  • Clean the medical instruments prior to CIDEX OPA
  • Testing the CIDEX OPA Solution
  • How to Use CIDEX OPA
  • Disinfection Procedure
  • Rinsing the Instruments
  • Drying the Instruments
  • Disposal of used CIDEX Solution

Wearable Your Personal Protective Equipment

It is vital that personnel always clothing their personal protective equipment every bit they handle the contaminated medical devices, sterilization products and instruments that crave decontaminating. Vesture a fluid-repellent gown, gloves and eye protection during the unabridged decontamination process.

Discolored skin, mucous membranes and stained clothing or other surfaces are to exist expected if they come into contact with the CIDEX OPA Solution. If skin contact is made, wash the expanse with lather and water for several minutes. Any discoloration will disappear within a couple of days. Avoid contact with floors, walls, and counters. Specific trays are manufactured to use in the disinfection procedure to avoid skin contact, spilling, splatter and contact with other surfaces.

Clean the medical instruments prior to CIDEX OPA

Before the advanced sterilization and high-level disinfection can brainstorm, a thorough bones cleaning of the medical devices and instruments is required. All semi-critical medical devices reprocessed in CIDEX OPA Solution must first be cleaned according to a validated cleaning protocol or standard, such equally the ASTM F 1518 "Usa Standard Practice for Cleaning and Disinfection of Flexible Fiberoptic and Video Endoscopes Used in the Examination of the Hollow Viscera."

  • Remove all debris. Completely clean all of the surfaces of the devices and instruments, inside and out. Clean all lumens of any hollow instruments like flexible endoscopes with any balmy detergent designed to dissolve proteins, like ENZOL Enzymatic Detergent.
  • Highly acidic or highly alkaline detergents are not appropriate cleaning agents for use with CIDEX OPA Solution. Utilise only a mild enzymatic detergent, neutral in pH, that is low foaming, and can be easily rinsed from the medical devices and instruments.
  • Afterward a thorough cleaning, rinse every surface with copious amounts of make clean water to be certain the detergent rest has been removed
  • Advisedly remove excessive amounts of water left after the rinsing since the h2o will dilute the CIDEX OPA Solution and interfere with the disinfection and sterilization products. If the CIDEX is diluted below a minimum constructive concentration (MEC) it will exist necessary to echo the disinfection procedure with fresh solution.

Each medical device and instrument volition be labelled with manufacturer'south instructions for cleaning, decontaminating, disassembly and reassembly as well equally leak testing. Exist sure to bank check those instructions for each device.

Testing CIDEX OPA Solution

The CIDEX OPA Solution requires testing earlier each utilize. CIDEX OPA Solution Test Strips are used to confirm that the level of concentration of the ortho-phthalaldehyde meets the minimum constructive concentration (MEC) required for high-level disinfection. The MEC required is 0.iii%. Fifty-fifty if the concentration level remains loftier enough, the disinfection and sterilization products are still discarded after two weeks. Check the CIDEX OPA test strips package insert for detailed instructions.

How to Use CIDEX OPA Solution

Circumspection: Always read the directions on the parcel insert and the label before each use.

CIDEX OPA Solution does not require activation or mixing. Simply open the bottle and pour the solution directly into a CIDEX solution tray or another suitable container.

  • An unopened bottle has a long shelf life, assuasive it to be stored in appropriate weather for two years. An opened bottle must be used within 75 days.
  • But use CIDEX OPA Solution in a validated reprocessing procedure in an automatic flexible endoscope reprocessor. Proceed records of the dates your solutions are poured from the containers and calculate when the date the reuse life volition end, which must be not more than than 14 days. Nosotros recommend using a CIDEX OPA log sheet to keep track of this.

Disinfection Procedure

  • The clean, mostly dry devices can now be immersed completely in the sterilization disinfecting solution.
  • Fill any lumens.
  • Fit the tray cover onto the tray.
  • Soak for 12 minutes at room temperature (20º C) to achieve the high-level disinfectant standard.

Rinsing the Instruments

Post-obit the disinfection, the instruments must be rinsed thoroughly.

  • Affluent whatsoever channels with a sterile water source.
  • Rinse each medical device three times.
  • Rinse for a minimum of one minute, using at least two gallons of clean water each fourth dimension.
  • Avant-garde Sterilization Products (the manufacturer) recommends using sterile h2o unless beverage h2o is acceptable.

Drying the Instruments

Each medical device and instrument must at present exist thoroughly stale. The disinfected medical equipment is at present set for use. If it is to exist stored, be careful to store it while because the hazard of recontamination.

Disposal of the Used CIDEX Solution

Used CIDEX OPA Solution can usually be discarded downwardly the drain at the hospital or doctor's office. Always bank check your local regulations before disposing down a drain. if required, glycine (gratuitous base) may exist used as a neutralizer for CIDEX OPA Solution prior to disposal. A minimum of 25 grams of glycine (free base of operations) should be used to neutralize 1 gallon of CIDEX OPA Solution. The minimum recommended neutralization time is one hour. After discarding the solution into drain, flush drain thoroughly with water.

Ortho-phthalaldehyde, the FDA and the CDC

In Oct of 1999, the Nutrient and Drug Administration (FDA) approved the use of ortho-phthalaldehyde for use as an advanced sterilization high-level disinfectant. The FDA canonical ortho-phthalaldehyde considering studies found what were described every bit "excellent microbiocidal activity in in-vitro studies." According to the Centers for Affliction Control and Prevention, ortho-phthalaldehyde eliminated several microorganisms, such every bit mycobacateria and Bacillus subtilis spores. These microorganisms were found to be resistant to glutaraldehyde solutions, which was usually used at the fourth dimension.

Quick and Easy High-Level Disinfection

Time spent in non-patient care in medical facilities is always at a premium.

  • A quick five-minute soak at 25°C in automated flexible endoscope reprocessors, or for 12 minutes at twenty° C with manual processing, makes CIDEX disinfectant a quick way to achieve loftier-level disinfection.
  • Rut-sensitive medical devices are preserved, and the highest level of disinfection is achieved, quickly and efficiently.
  • The lack of activation, mixing or other preparation saves time. The fix-to-use disinfection and sterilization products solution means disinfecting begins equally before long every bit the initial cleaning is complete.
  • A quick soak, a thorough rinse and a dry, and loftier-level disinfectant is achieved.

Safety Precautions

Disinfecting instruments, medical devices and equipment e'er requires care and special attention.

  • CIDEX disinfectant is frequently preferred since it is virtually odorless.
  • CIDEX does not require any special ventilation since it does not crusade irritation to the eyes or nasal passages, just it is best to use in a well-ventilated area.
  • Avoid contact with eyes, peel, and clothing. Always exist sure to clothing a fluid-repellent gown, gloves and protective eyewear when handling the fluid and equipment, as CIDEX does stain.

Disadvantages

  • CIDEX OPA stains pare with contact. It stains mucous membranes. Information technology stains clothing. It stains counters, walls or floors.
  • Staining volition occur with straight contact such as a spill, simply too can occur if instruments or equipment are not rinsed well enough and they come into contact with patient skin or mucous membranes. Exist sure to rinse all disinfected items thoroughly.
  • Directly contact with eyes and skin may crusade irritation. Repeated contact with skin may cause skin sensitization.
  • CIDEX OPA Minimum Effective Concentration (MEC) must be verified by a CIDEX OPA Solution Test Strip prior to each use to determine that the concentration of ortho-phthalaldehyde is above the MEC of 0.iii%.

Frequently Asked Questions

How to remove a CIDEX stain?

The short reply is, yous probably can't. It just takes a couple of days for the grayness stain to fade on skin or mucous membranes.

On equipment, the area tin be wiped clean with seventy% isopropyl alcohol and a lint-free cloth if the manufacturer's instructions allow it. This process will minimize staining but doesn't completely eliminate long-term potential stains. Often it volition non remove any existing stain.

What does CIDEX OPA kill?

CIDEX has been tested and proved to minimize the growth rates of a wide range of various bacteria, including:

  • Staphylococcus aureus
  • Salmonella choleraesuis
  • Pseudomonas aeruginosa
  • Methicillin-resistant Staphylococcus aureus (MRSA)
  • Vancomycin-resistant Enterococcus faecalis (VRE)
  • Staphylococcus aureus
  • Enterococcus hirae
  • Pseudomonas aeruginosa

CIDEX has been tested to kill these diverse viruses:

  • Adeno ii
  • Virucidal Coxsackie Type B- 3
  • Virucidal Cytomegalovirus
  • Virucidal Herpes Simplex Type ane & 2 (HSV1 & HSV2)
  • Virucidal HIV-1
  • Virucidal Human Coronavirus
  • Virucidal Flu Type A (Hong Kong)
  • Virucidal Polio 1
  • Virucidal Rhinovirus Type 42
  • Virucidal Vaccinia

CIDEX has been tested to kill these types of spores:

  • Clostridium sporogenes
  • Bacillus subtilis

How Toxic is CIDEX OPA Solution?

CIDEX OPA Solution has been studied extensively to determine its toxicity. The results demonstrate the disinfection and sterilization products solution to be safe when it is used as directed. It may cause heart, skin, and respiratory irritation. Employ CIDEX OPA in a well-ventilated area with personal protection equipment. For more than details, run across the CIDEX OPA Material Safety Data Sheet.

How does CIDEX OPA Solution Compare to Metricde OPA Plus Solution?

MetriCide OPA Plus Solution is similar to CIDEX OPA Solution. The MetriCide OPA contains a slightly greater amount of the agile ingredient. They are both every bit stable, safe, and effective. They both have a long shelf life and the same materials compatibility. The MetriCide OPA Disinfectant Solution tin can exist used more frequently inside a two-week period, which tin help busy medical facilities save costs.

What is the deviation between CIDEX Activated Dialdehyde Solution and CIDEX OPA? Which one is better for bladder cancer patients?

CIDEX OPA is unlike from CIDEX Activated Dialdehyde Solution. CIDEX Activated Dialdehyde Solution uses glutaraldehyde as the disinfectant while CIDEX OPA uses ortho-phthalaldehyde. Bladder cancer patients are more than sensitive to ortho-phthalaldehyde. CIDEX OPA should not exist utilized to process any urological instrumentation used to treat patients with a history of bladder cancer.

What is the divergence between peracetic acid and CIDEX products?

Peracetic is highly constructive and is used as an culling to glutaraldehyde. The acrid has a vinegar smell simply can exist somewhat less irritating to some. Peracetic acid must be used in frazzle-ventilated or sealed facilities. It is significantly more expensive, less stable, has a shorter shelf life, and only large volumes can be stored. Corrective damage is acquired to endoscopes, and this acrid is not universally compatible with disinfectors and washers.

What are the CIDEX OPA Solution Examination strips and what are they used for?

CIDEX OPA Test Strips are designed to be used to test the CIDEX OPA disinfectant solution before each employ. The test strips measure the MEC (minimum effective concentration) of the disinfectant solution. They are simple to utilize and read.

CIDEX OPA and CIDEX Activated Dialdehyde Solution are industry standards for high-level disinfection. In that location are many benefits such as efficacy, a long shelf life, and ease of use, proving an fantabulous choice for any facility requiring infection prevention. Hospitals, dentists, physician'due south offices, clinics, surgeries and veterinary care locations beyond the country are all achieving loftier-level disinfection with CIDEX OPA and CIDEX solutions. CIDEX products are manufactured by Advanced Sterilization Products, a segmentation of Ethicon (a Johnson & Johnson company).

CIDEX OPA is an constructive medical musical instrument disinfectant and it is not to be used on skin. For a pare antiseptic and antimicrobial peel cleanser apply Hibiclens. Hibiclens gently and effectively cleanses skin and superficial wounds and can protect the skin for up to 24 hours. For more information on Hibiclens see our web log article Hibiclens: Antiseptic Skin Cleanser.

CIDEX OPA and a broad range of CIDEX products are bachelor through USAMedicalSurgical.com. Not all CIDEX products are listed on the website, and so if you do non discover what you lot are looking for, please telephone call for pricing and availability on our toll-free number (888-215-0718), or electronic mail us at  sales@usamedicalsurgical.com.